<spdrs60.BlockTf71>

back to index
Configuration of Tf71 block

Description

The default wireing over J2 for this element is described on this website. This is the user interface for the element that was configured to Elekdra in <elekdra.fieldblock>. If this element is used for a track with bidirectional traffic, you need to configure the permission field for the same block with <spdrs60.BlockPermission>

Example

Configuration of Tf71 'BlA' that uses default mapping with board 'BlAtf' for the blue Ausfahrsperrmelder and RblT.
<spdrs60.BlockTf71>
	<name>BlA</name>
	<board>BlAtf</board>
</spdrs60.BlockTf71>

Sub tags

Tag Description
<TrackRed>
Type: OutputAddress
Cardinality: optional [0..1]
Track indicator red (occupancy)
<Blue>
Type: OutputAddress
Cardinality: optional [0..1]
Ausfahrsperrmelder
<RblT>
Type: InputAddress
Cardinality: optional [0..1]
Rückblocktaste
<name>
Type: String
Cardinality: once
Name of the element as given in Elekdra configuration.
This is used as reference for communication on the user interface TCP connection to Elekdra.
<board>
Type: String
Cardinality: optional [0..1]
Bord for default wiring
This references to tags <spdrs60.s60v2> or similar. If no default wiring is used, this can be omitted. For default wiring, this tag referres to wiring specifies on this website.

Generated by ConfigFileDocumentationGenerator Valid HTML 4.01 Transitional