<spdrs60.Track.J1>

back to index
Track wired over J1

Description

The default wireing for this element is described on this website. Don't use 'Gelb' and 'Rot' in this case! This is the user interface for the element that was configured to Elekdra in <elekdra.track>.

Example

Indicators of district 'A43' are wired with default wiring of J1 of board 'foo'
<spdrs60.Track.J1>
	<name>A43</name>
	<board>foo</board>
</spdrs60.Track.J1>

Sub tags

Tag Description
<Resettable>
Type: boolean
Cardinality: optional [0..1]
Track key for axle counter reset present?
Set to true if the default button at J1 IN1 shall be able to perform a reset operation on the track. This can be a reset of an axle counter district.
<name>
Type: String
Cardinality: once
Name of the element as given in Elekdra configuration.
This is used as reference for communication on the user interface TCP connection to Elekdra.
<board>
Type: String
Cardinality: optional [0..1]
Bord for default wiring
This references to tags <spdrs60.s60v2> or similar. If no default wiring is used, this can be omitted. For default wiring, this tag referres to wiring specifies on this website.

Generated by ConfigFileDocumentationGenerator Valid HTML 4.01 Transitional